Measurement of scintillation efficiency for nuclear recoils in liquid argon

Gastler, D., Kearns, E., Hime, A., Stonehill, L.C., Seibert, S., Klein, J., Lippincott, W.H., McKinsey, D.N. and Nikkel, J.A.

(2012)

Gastler, D., Kearns, E., Hime, A., Stonehill, L.C., Seibert, S., Klein, J., Lippincott, W.H., McKinsey, D.N. and Nikkel, J.A. (2012) Measurement of scintillation efficiency for nuclear recoils in liquid argon. Physical Review C, 85 (6).

Our Full Text Deposits

Full text access: Open

Full text file - 1.11 MB

Links to Copies of this Item Held Elsewhere


Abstract

The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr at zero electric field. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25±0.01+0.01 (correlated) above 20 keVr. © 2012 American Physical Society.

Information about this Version

This is a Submitted version
This version's date is: 27/6/2012
This item is not peer reviewed

Link to this Version

https://repository.royalholloway.ac.uk/items/3ba96f94-3833-fe80-4021-d4ab23601810/2/

Deposited by Research Information System (atira) on 27-Jan-2013 in Royal Holloway Research Online.Last modified on 27-Jan-2013

Notes

Copyright 2012 Elsevier B.V., All rights reserved.


Details